Home › G-codes › Mitsubishi M70 M80 › G05
G05 High speed high accuracy control II and III
Mitsubishi M70 M80 G-code · Mill
G05 P10000 turns on high speed high accuracy control II for fast small block 3D programs. G05 P20000 is type III on M800. G05 P0 cancels.
Format
G05 P10000 or G05 P0
Addresses
| Address | What it does |
|---|---|
P10000 | High speed high accuracy control II on |
P20000 | High speed high accuracy control III on, M800 |
P0 | Cancel |
How it works
Modal until canceled with G05 P0 or reset.
Example program
G05 P10000 (HIGH SPEED HIGH ACCURACY II ON)
M98 P8100 (3D FINISH PATH)
G05 P0 (CANCEL)
M98 P8100 (3D FINISH PATH)
G05 P0 (CANCEL)
Example is in inch. Check offsets and clearances first.
Watch out for
- Option function. Command it in a block by itself.
- Cutter comp and some other functions are limited in this mode. Check the manual list.
- Mitsubishi G05 is not the Fanuc G05 data server or AI contour command.
Related codes
G05 on other controls
The same number can mean something different on another control.
| Control | Meaning |
|---|---|
| Mazak (EIA) | High speed machining mode |
| Heidenhain TNC (ISO) | Arc without direction, Cartesian |
| Fagor 8055 8065 | Round corner |
| LinuxCNC Tormach | Cubic spline |
| Fadal | Non modal rapid travel |
Every G-code for Mitsubishi M70 M80 in your pocket. The app has the full example programs, search by number or shop word, a line decoder and calculators for tapping, threading and drilling.
Open G05 in the app All Mitsubishi M70 M80 G-codes